Cobra Classic Comfort Plus Nomex® (Meta‑Aramid) and Lenzing FR® Firefighting Hood

30200-00-181085

Cobra Classic hoods provide double layer coverage of neck, upper chest and top of the shoulder blades. The notched side helps bib lie flat for improved interface with bunker coat. Flat-stitched seams eliminate bunching and won’t dig into skin. A half inch wide elastic face opening stretches to full 17" to ensure a snug fit around most SCBA masks. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition.

Fabric Description:

Developed by PGI in the early 1980s, this mid-weight blend has become the most popular hood fabric in the market due to its ability to wick moisture away from the skin more effectively than other flame resistant fabrics keeping the wearer drier and more comfortable.

Sizing:

One size fits most

Options:

Thread
Cobra hoods are available sewn with either color-coordinated (matching) or color-contrasting 100% Nomex® thread.
Direct Embroidery
100% Nomex® thread embroidered on bib. Minimum order 25 each.
Ink Heat Transfers
High resolution multi-color transfers. Minimum order 100 each.

Features

Test Results

Fabric Performance ValuesRequirements NFPA 1971
2018 Edition
PGI Test Results
Thermal Protective Performance (TPP)
  • As Received
20.0 (min)27.5
  • After 5 Washings
20.0 (min)26.5
Hood Material Burst Strength 225 N374 N
Flame Resistance Test

After Flame (Wales x Courses)

  • As Received
2.0 sec0.0 sec x 0.0 sec
  • After 5 Washings
2.0 sec0.0 sec x 0.0 sec

Char Length (Wales x Courses)

  • As Received
100 mm39 mm x 38 mm
  • After 5 Washings
100 mm33 mm x 38 mm
Cleaning Shrinkage Resistance Test

Hood Measurement

  • After 5 Washings
-5%-0.7% to -0.3%
Heat & Thermal Shrinkage Resistance Test

Hood Measurement

  • As Received
-10%-2.4% to 0.0%
  • After 5 Washings
-10%-1.3% to 2.0%
Limited Oxygen Index (LOI)Not Required29
Seam Breaking Strength Test 181 N1265 N
Melt or Drip When Exposed to FlameNo Melting or DrippingNONE
Arc Thermal Performance Value (ATPV)10 cal/cm2
NFPA 70E Hazard Risk Category (HRC)HRC 2

Product Line

Cobra<sup>™</sup> Classic<sup>™</sup> PBI/Lenzing FR<sup>®</sup> with Comfort Plus<sup>™</sup> Liner

Cobra Classic PBI/Lenzing FR® with Comfort Plus Liner

Cobra<sup>™</sup> Classic<sup>™</sup> Comfort Plus<sup>™</sup> Nomex<sup>®</sup> (Meta‑Aramid) and Lenzing FR<sup>®</sup>

Cobra Classic Comfort Plus Nomex® (Meta‑Aramid) and Lenzing FR®

Cobra<sup>™</sup> Classic<sup>™</sup> Ara‑Tek FR<sup>™</sup> Tri‑Blend

Cobra Classic Ara‑Tek FR Tri‑Blend

Cobra<sup>™</sup> Classic<sup>™</sup> Kermel<sup>®</sup> and Lenzing<sup>®</sup> FR

Cobra Classic Kermel® and Lenzing® FR

Cobra<sup>™</sup> Classic<sup>™</sup> Carbon Shield<sup>™</sup>

Cobra Classic Carbon Shield

Cobra<sup>™</sup> Classic<sup>™</sup> 100% Nomex<sup>®</sup> Meta‑Aramid

Cobra Classic 100% Nomex® Meta‑Aramid