Cobra Ultimate hoods are double ply and feature extra-long length that covers head, chest, shoulders and shoulder blades for enhanced protection. Flat-stitched seams eliminate bunching and won’t dig into skin. A half inch wide elastic face opening stretches to full 16" to ensure a snug fit around most SCBA masks. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition.
Nomex® has excellent thermal stability and will not melt or drip. Fabric has outstanding strength, abrasion resistance and chemical resistance.
Thread
Cobra hoods are available sewn with either color-coordinated (matching) or color-contrasting 100% Nomex® thread.
Direct Embroidery
100% Nomex® thread embroidered on bib. Minimum order 25 each.
Ink Heat Transfers
High resolution multi-color transfers. Minimum order 100 each.
Fabric Performance Values | Requirements NFPA 1971 2018 Edition | PGI Test Results |
Thermal Protective Performance (TPP) | ||
| 20.0 (min) | 27.1 |
| 20.0 (min) | 27.1 |
Hood Material Burst Strength | ≥ 225 N | 716 N |
Flame Resistance Test | ||
After Flame (Wales x Courses) | ||
| ≤ 2.0 sec | 0.0 sec x 0.0 sec |
| ≤ 2.0 sec | 0.0 sec x 0.0 sec |
Char Length (Wales x Courses) | ||
| ≤ 100 mm | 39 mm x 39 mm |
| ≤ 100 mm | 32 mm x 37 mm |
Cleaning Shrinkage Resistance Test | ||
Hood Measurement | ||
| ≥ -5% | -1.0% to -0.7% |
Heat & Thermal Shrinkage Resistance Test | ||
Hood Measurement | ||
| ≥ -10% | -1.5% to 0.0% |
| ≥ -10% | -0.1% to 1.5% |
Limited Oxygen Index (LOI) | Not Required | 31 |
Seam Breaking Strength Test | ≥ 181 N | 1394 N |
Melt or Drip When Exposed to Flame | No Melting or Dripping | NONE |